Updated Requirements to the NFPA 61 Standard
The National Fire Prevention Association has published updated requirements to its NFPA 61 standard for preventing fires and dust explosions in agricultural and food processing facilities.
While food manufacturers generally have until 2021 to comply, undertaking the initiative sooner could potentially save you time and money, as you integrate process equipment upgrades with the implementation of a revised combustible dust strategy.
Review of Recent Changes
NFPA 61 provides guidance on combustion risks in facilities handling, processing, or storing bulk agricultural materials, their by-products, or other agricultural-related dusts and materials. Although NFPA standards are not federal law, they become legally binding in local and state municipalities that have adopted them as regulatory code. In addition, OSHA can reference NFPA standards when levying fines for unsafe work environments under the General Duty clause.
Clarification to Combustible & Explosible
The new version of NFPA 61 better aligns with NFPA 652, “Standard on the Fundamentals of Combustible Dust,” to offer clarification on how to determine whether materials present in a process are combustible or explosible. This is an important responsibility for the owner or process operator, and needs to be the first step in a risk mitigation plan.
Guidance on Conducting a DHA
The standard also introduces guidance on conducting a Dust Hazard Analysis (DHA). If you have potentially combustible or explosible material in your facility, a DHA is developed to identify and address the risks present. NFPA 61 describes the methodology for a DHA and gives an example checklist. For facilities with existing equipment, the standard lists a completion date of June 2021. For any new process or existing processes to be significantly changed, then a DHA must be completed as part of the project.
Performance-Based Design Methodology
The standard also contains a new section on the methods and requirements for the Performance-Based Design option for risk mitigation. This option gives the process owner the flexibility to use alternative solutions based on good engineering principles and documentation in addition to the prescriptive requirements outlined in NFPA 61.
Process Review
Food processing facilities have been a leader in addressing combustible dust risks, but now some of those early systems are aging or out of date, and new technologies are available to upgrade them. At the same time, the Food Safety Modernization Act (FSMA) and increased production rates may be driving facilities to make changes in their food manufacturing processes. For this reason, it likely makes sense to combine the process equipment review with dust collection system evaluations if you are considering replacing aging systems. This review approach can help you address combustible dust risks while highlighting a strategy that may integrate better with your production process and provide an optimized system.
Risk Mitigation Options
The process owner responsible for a DHA and mitigation strategy should consider different options for effective risk mitigation. These include:
Facility Housekeeping
Some facilities with devastating events looked fastidious on the surface but ignored dust accumulations on suspended ceilings, light fixtures, or girders. If an initial explosion disturbs this dust, it becomes suspended fuel for a secondary, building-wide deflagration. Make sure you inspect and periodically clean all surfaces from floor to ceiling, including walls, avoiding accumulations.
Dust Containment
Furthermore, removing dust from the air prevents it from accumulating on surfaces. An effectively designed dust collection system uses hoods to capture dust and the airflow transports it via duct to a dust collector. Food manufacturers in particular may have valid reasons for preferring indoor installations — and with today’s engineering advances that is more viable. Once the airflow requirements are known, then a dust collector can be chosen for the application and outdoor or indoor location reviewed, based on the equipment and strategy that works best for your facility and needs.
Mitigation Equipment
Both prevention and protection equipment options should be reviewed and considered for your mitigation strategy. A variety of equipment options are now available, including
- active and passive isolation devices
- explosion venting options
- fire or explosion suppression systems