SGS - Local Case Study
Local Case Study
Industry: Mining
The Client
The Challenge
In one of their buildings at Lakefield Ontario, they crush and blend rocks in an
enclosed room (65’L x 45’W x 13.5’H). When they operate, the airborne concentration of dust is too high which causes loss of visibility in 3-5
minutes. Therefore, they required a dust collection system to remove the dust cloud and reduce the dust concentration without interfering with
the operation. The system needed to match the following design criteria:
- Constant air exchanges
- Special capture hoods and diffusers, and duct design to eliminate any interference with floor space with no head room issues
- High efficiency filtration system in order to return the clean air and save on energy (reclaim heated air)
The Solution
The solution was ambient capture (push & pull system). AST installed a 20,000 CFM dust collector for capturing and filtering the abrasives for
the crushed rock dust. This amount of airflow creates an air exchange every 2 minutes in the room which keep the visibility and air quality at
an acceptable level. Therefore, the airborne dust is getting captured and filtered during the hours of operation constantly. Note: AST provided
the client with 3D design drawings of the installation and coordinated with the mechanical installer to make sure everything was installed based
on the design.
The Equipment
- One (1) VH 2-12 PowerCore dust collector
- One (1) AST-HDBI-300 BI centrifugal floor-mounted 50HP TEFC fanne
- (1) inlet box and inline silencer
- One (1) AST-CP-50HP-575V control panel including w/ Delta P Plus controller