Hours
Office: Mon – Fri    8:30am – 4:30pm
Emergency: 24/7

Bubble Tight Isolation Dampers

To isolate filtration trains during shutdown

Continental Carbon Barnebey Sutcliffe Bubble tight damper hero | AST Canada
AST Canada provides Bubble Tight Isolation Dampers to isolate critical filter trains or environmental emissions during a shutdown ensuring air emissions compliance.

BDT Series Isolation Damper

The BTD is designed for the isolation of critical filter trains or environmental emission control systems during change-out, decontamination, shutdown, and/or testing services without disabling the entire system or risking air emissions that could affect compliance. Damper operation can be manual or electric. Dampers can be manufactured out of 304 stainless steel. Other materials are available upon request.

Bubble Tight Isolation Dampers can be used in:

  • Room isolation
  • Containment housings
  • Dust collectors
  • HVAC
  • Building isolation systems

ANSI Bubble Tight Certification

 

The damper is also available with a bubble tight certification per ANSI test method N510-1980. In a hazardous atmosphere, the Series BTD Isolation Damper enables the system to be isolated for decontamination, filter change-out or to allow scan testing by an auxiliary air supply system. In a nonhazardous atmosphere, it prevents particulates or vapor phase chemical contaminates from reaching the atmosphere or other equipment and processes to which the system being isolated may be connected.

BTD Design Specifications

BTD Series Bubble Tight Isolation Dampers - round and square | AST Canada

Round or Squared Duct

BTD Isolation Dampers are available for either round or square duct in temperatures ranging from -50º F to 375º F. The damper is designed with a single blade mounted to a shaft with a fabricated flange frame. The damper contains a full circumference silicone blade seal that is retained by a steel clamp ring fastened by hex nuts. Manual or electric actuators can be supplied as required.

The blade seal is field adjustable and replaceable. The shaft is supported in self-lubricating TFE lined filament wound bearings mounted external to the damper frame with O-ring shaft seals.

Standard sizes range from 8″ to 36″ round and custom sizes are also available.

The square BTD attaches directly to the containment housing, which eliminates the need for transitions between the housing and damper as is required when using the round BTD. Damper housing is 24″ square duct with a flange total width of 27″; a total flange height of 30″; and adds 26½” to the length of the containment unit. Damper operation can be manual, electric, or pneumatic.

Bubble-tight Isolation Damper Dimensional Diagram | AST Canada
Fig.! - Bubble-tight Isolation Damper Dimensional Diagram
Round Bubble-tight Isolation Damper
Round Bubble-tight Isolation Damper
 

 

BDT Series Bubble Tight Isolation Damper Dimensional Chart

Please refer to fig. 1 above

AB  CDE 
Inside
Diameter
(inches)
Bolt Hole
Diameter
(inches)
Bolt Hole
Quantity
Bolt Hole
Cirlce Diameter
(inches)
Flange
(inches)
Width
(inches)
Depth
(inches)
Approx.
Weight
(lbs.)
87⁄1681011932
107⁄16121213940
127⁄161213¾15¼947
147⁄16121617955
167⁄16161819957
187⁄16162021965
209⁄16202324⅜964
229⁄16202526988
249⁄16242728⅜998
269⁄162429230998
309⁄162432½23412140
369⁄163238½24012197
Larger & Custom sizes are available

 